.
Description
Technical Specifications
Benefits and Features
Equipment
360 View
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications | |
Maximum Rating | 450 ekW |
Minimum Rating | 450 ekW |
Emissions/Fuel Strategy | EPA Stationary Emergency |
Voltage | 480 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 RPM |
Duty Cycle | Standby |
Engine Specifications | |
Engine Model | Cat® C15 In-line 6, 4-cycle diesel |
Bore | 5.4 in |
Stroke | 6.8 in |
Displacement | 928 in³ |
Compression Ratio | 16.1:1 |
Aspiration | Turbocharged Air-to-Air Aftercooled |
Fuel System | MEUI |
Governor Type | ADEM™A4 |
Generator Set Dimensions | |
Length - Maximum | 189.6 in |
Width - Maximum | 64.2 in |
Height - Minimum | 80.1 in |
Height - Maximum | 101.7 in |
Dry Weight - Genset (minimum) | 8172.5 lb |
Dry Weight - Genset (maximum) | 10238.3 lb |
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.2 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to104°F (40°C)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- UL 2200 Listed
- ULC Certification Available
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment:
-
- Air Inlet System
-
- Aftercooler core
- Turbocharger
- Air cleaner - Non canister, disposable
-
- Control Panel
-
- GCCP 1.2
-
- Cooling System
-
- Thermostats and housing
- Blower fan and fan drive with guards
- Radiator, package mounted
- Coolant drain valve
- Jacket water pump, gear driven, centrifugal
- Radiator sight gauge
-
- Exhaust System
-
- Exhaust manifold - dry
-
- Fuel System
-
- Fuel priming pump
- Integral tank base, 24 hours, UL142
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Engine fuel transfer pump
- Fuel cooler
-
- Generator Set
-
- Complete system designed & built at ISO 9001:2000 certified facilities
- Factory tested to design specifications at full load conditions
- All protective devices and control functions simulated and checked
-
- Generators And Generator Attachments
-
- IP23 Protection
- Voltage regulator (single phase sensing)
- Easy access to AVR and terminals
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
- Terminal box, IP22 RHS facing, bottom cable entry
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- 6 Leads
- Insulation system, Class H
-
- Governing System
-
- Cat electronic governor (ADEM A4)
-
- Lube System
-
- Fumes disposal to front of radiator
- Oil filter, spin on
- Lubricating oil, CK-4 (10W-30)
- Shallow oil pan
- Oil cooler
- Oil filler and dipstick
- Oil drain with valve
-
- Mounting System
-
- Includes lifting provisions and termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
-
- Protection
-
- Safety shutoff - Low oil pressure
- Safety shutoff - Overspeed
- Safety shutoff - High water temperature
-
- Starting/charging System
-
- 24-volt electric starting motor
- 24V, 45 Amp Charging alternator
-
- General
-
- Vibration damper
- Parts book
- Lifting eyes
Optional Equipment:
-
- Air Inlet System
-
- Air cleaner (Non canister disposable)
-
- Bases, Mounting & Fuel Tanks
-
- Overfill prevention valve
- Wide Base - Skid
- Audio & visual fuel alarm (@90% fuel level)
- Integral tank base, 24 hours, UL142
- Fuel tank pill pipe & lockable cap
- 5 Gallon Spill Containment
-
- Exhaust
-
- Industrial, residential, critical mufflers
-
- Circuit Breaker
-
- 400A LSI
- 400A LS/I
- 800A LSI
- Auxiliary contacts
- 600A LS/I
- 1200A LSI
- 600A LSI
- 1200A LS/I
- 800A LS/I
-
- Control System
-
- Volt free contacts
- 100A Load center
- Product link remote monitoring hardware
- Twist release, Red button emergency stop
- 16 -light NFPA 99/110 Annunciator
- 20A GFCI (Ground Fault Circuit Interrupter)
- Audible alarm Gp
- Ground fault relay
-
- Enclosures
-
- E-Stop
- AC & DC Source lights
- Sound attenuated Level 2 enclosure (White)
-
- Generator
-
- Anti-condensation heater
- Oversize and premium generators
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Permanent magnet excitation (PMG) generator
- Space heater
-
- Exhaust System
-
- Manifold and turbocharger guards
- Flexible exhaust connection
- 8" Muffler - 25 dBA attenuation
-
- Starting System
-
- Standard battery set: 1000 CCA, 90 amp/hr.
- Oversize battery set, 1400 CCA, 200 amp/hr
- Battery charger (UL Certified)
- Jacket water heater
-
- Power Termination
-
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
-
- General
-
- UL2200 Certification
- CSA Certification
- Extended Service Coverage
- Generator test report
- CSA Certification
- UL 2200 package
-
- Lube System
-
- Manual sump pump
-
- Mounting System
-
- Narrow skid base - replaces standard fuel tank base