Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

D50 GC Generator Set

.
🔍

 

Description
Technical Specifications
Benefits and Features
Equipment
360 View

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Maximum Rating 50 ekW
Minimum Rating 50 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C4.4, In-line 4, 4-cycle diesel
Bore 4.1 in
Stroke 5 in
Displacement 269 in
Compression Ratio 18.2:1
Aspiration Turbocharged
Fuel System Common Rail
Governor Type Mechanical, ADEM™A4
Generator Set Dimensions
Length - Maximum 77.2 in
Width - Maximum 43.3 in
Height - Maximum 48 in
Dry Weight - Genset (maximum) 2055 lb

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

M-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL 2200 Listed
  • ULC Certification Available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment:

  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Air cleaner
    • Cartridge type air filter
  • Circuit Breakers
    • Second circuit breaker box
    • Power terminal strip
    • Breakers (100% UL rated)
    • 3-Pole 100% rated
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Radiator stone guard
  • Control Panels
    • NFPA110 bundle includes:
    • WCA1 Low coolant temperature alarm
    • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • WSS1 Low coolant level shut down
    • PBC10NU NFPA battery charger
    • Oil temperature gauge and sender
    • PAA1 Panel mounted audible alarm
    • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Audible alarm
    • Remote E-stop button
    • Ground fault relay
    • Discrete I/O module
    • Remote annunciator module
    • Volt free contacts genset run and common alarm
    • Fuel level reading
    • Protective devices:
    • Low coolant temperature alarm
    • Low coolant level shutdown
    • Overload shutdown via breaker
  • Generator
    • 12 Leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Starting/charging System
    • Batteries
    • 24V battery with rack and cables

Optional Equipment:

  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Cartridge type air filter
  • Alternator System
    • R Frame auxilliary winding
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • Breakers (100% UL rated)
    • Power terminal strip
    • 3-Pole 100% rated
    • Second circuit breaker box
  • Control Panels
    • Volt free contacts genset run and common alarm
    • Oil temperature gauge and sender
    • Remote E-stop button
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Audible alarm
    • Remote annunciator module
    • Discrete I/O module
    • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Ground fault relay
  • Cooling System
    • Radiator transition flange
  • Enclosures
    • External emergency stop
    • Sound attenuated enclosure, Level 2
    • Panel viewing window
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
  • Fuel System
    • 5 Gallon spill containment
    • 209 and 394 gallon sub-base fuel tanks
    • Tank riser
    • Emergency vent pipe
    • 5 Gallon fill containment
  • Heating Elements
    • Coolant heater
    • Wiring for canopy space heater
    • Battery heater
    • Lube oil sump heater
    • Anti-condensation heater
    • Wiring for canopy space heater
    • Jacket water heater
  • Generators
    • Permanent magnet excitation (PMG) generator
    • Permanent magnet excitation (PMG) generator
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • 4 Hour factory test
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
    • Generator test report


Related Equipment